SANITIZER MENU |
|
|
|
|
The SANITIZER MENU is used to control the chlorine or bromine level in terms of sanitizer concentration (ppm or mg/l), which is obtained by conversion from ORP and pH values or from direct PPM sensor readings.
The sanitizer concentration readings can be calibrated to account for the
effect of cyanuric acid stabilization. |
The SANITIZER MENU includes selection of:
- Feed mode:
- Off
- Manual Feed
- Auto Feed with selection of:
- ON/OFF mode with adjustable deadband,
- Proportional mode with adjustable deadband and bandwidth,
- Timer with adjustable ON and OFF cycles
- Sensor calibration in ppm (choice of 1, 2 or 3 points),
- Control Setpoint in ppm,
- Low Alarm in ppm with optional buzzer and feed lockout,
- High alarm in ppm with optional buzzer and feed lockout,
- Time Limit with adjustable overfeed safety shutoff,
- Run Time displays for the current feed event and cumulative run time,
- Superchlorination and Chemical Saver (manual, weekly or multi-weekly programs).
NOTE: Sanitizer control can be done either under ORP control or under Sanitizer ppm control, at the choice of the operator.